motor supply, remote power switching employing 100, 200, and 350 amp power relays.
The system monitors the motor for high amperage, high temperature, or low voltage,
the relay will drop out the supply if any parameter is exceeded. There will be an
option for a latching relay power supply, and wireless remote control, including
motor reversing contactors in a IP56 enclosure.
cabin / deck lights, the unit will power two light circuits ( via internal circuit
breakers ) from a permanent live supply for a four minute time period. The system
monitors the main power isolator, when power is lost, the units powers two light
circuits to allow safe exit at night. If a light circuit is monitored, it can provide
back-up lights if a circuit fails, A daylight / ambient light monitor is included
to lockout the system when not required. 12 or 24 volt units, 2 x 10 amp outputs
engine room thermostat, the unit runs the engine bay fans on engine start up for
a period, and on shutdown depending on engine bay temperature, includes a low voltage
cut-out. The unit helps minimises engine room hotspots while engines cool. Also
in hot climates a reduction in the under floor heating effect from hot engines during
there cool down period. 12 or 24 volt units.
pump control, monitors pump start-up and running parameters. To start pump press
start button, if pump primes and runs at correct amperage the unit will lock in,
if the current drops due to the pump running dry, or increases due to a pump blockage,
the pump supply will drop out, the pump can also be stopped via a stop button.